FB#.RESKTR

Description

This parameter sets the resolver nominal transformation ratio. It affects the resolver excitation output amplitude.

The value is obtained from the resolver data sheet.

Context

See Feedback # View.

Versions

Action Version Notes
Implemented 02-00-00-000

General Information

Type

Read/Write

Units

N/A

Range

0.001 to 50.000

Default Value

0.5

Data Type

Float

See Also

N/A

Stored in Non-Volatile Memory

Yes

Variants Supported

All variants are supported.

Industrial Ethernet Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

FB1.RESKTR

3500h

04h

Unsigned16

-

1000:1

Read/Write

No

FB2.RESKTR

3501h

04h

Unsigned16

-

1000:1

Read/Write

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

30140

1

30140 (0x75bc)

FB1.RESKTR

Unsigned16

Read/Write

Yes

30141

1

30141 (0x75bd)

FB2.RESKTR

Unsigned16

Read/Write

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

FB1.RESKTR

30140

Float

Read/Write

-

FB2.RESKTR

30141

Float

Read/Write

-